Cold room panels demand total thermal bridge elimination, airtight eccentric cam-lock or double-labyrinth joints, and food-safe antibacterial surfaces. From +15°C processing rooms to -40°C blast freezers, SerPan Metal supplies complete cold storage packages including ceiling suspension gear, floor plywood, insulated sliding/hinged doors and curved PVC covings.

EN 14509 & CE
Custom Cut Length
Export & Truckload
Coordinated Trims
SYSTEM HIGHLIGHTS
Core Options: PUR • PIR • Taşyünü • EPS
Thickness Range: 40 mm – 200 mm
Steel Gauges: 0.40 – 0.70 mm (DX51D)
Fire Reaction: A1 Yanmaz / B-s1, d0
Max Length: 13.50 Metre (Firesiz)
TCMB Exchange Rate: 1 $ = 48,32 TL

* All prices EXW Factory excluding VAT.

WHY CHOOSE THIS SYSTEM?

Key Engineering & Commercial Benefits

Eccentric Cam-Lock Fasteners

Internal foamed-in steel hook locks compress joint gaskets hermetically without through-screws.

Double-Labyrinth Tongue & Groove

Stepped labyrinth profile completely eliminates thermal bridges between cold interior and warm exterior.

HACCP Food-Safe Antibacterial Surfaces

Certified 120µm antibacterial PVC film or AISI 304 Stainless Steel withstands aggressive sanitizing detergents.

40-42 kg/m³ High-Density Core

Maximum density closed-cell polyurethane matrix drastically reduces refrigeration compressor run-hours.

PRODUCT RANGE

Available Systems & Models

Select the optimal profile and core configuration for your building envelope requirements.

6 Systems Listed
Cold Storage Panel SP-COLD-WALL

Engineered with factory-embedded eccentric cam-locks or precision double labyrinth joints to ensure airtight seals, eliminating energy losses in cold rooms from +4°C down to -40°C.

Modular Width 1000 mm – 1150 mm
Fire Class B-s2, d0 / B-s1, d0
Reference Price
$23.00/ m²
EXW TurkeyExcl. VAT
Cold Storage Panel SP-COLD-CEIL

Suspended ceiling panels equipped with aluminum T-profiles and thermal-break tie rods to support ceiling loads while preventing condensation and frost formation.

Modular Width 1000 mm
Fire Class B-s2, d0 / B-s1, d0
Reference Price
$23.00/ m²
EXW TurkeyExcl. VAT
Cold Storage Panel SP-COLD-FLOOR

High compressive strength flooring designed to withstand static and dynamic rolling wheel loads while eliminating ground frost heaving.

Modular Width 1000 mm
Fire Class B-s2, d0
Reference Price
$26.00/ m²
EXW TurkeyExcl. VAT
Cold Room Door SP-COLD-DOOR

High-frequency industrial cold doors engineered with anodized aluminum hardware, safety inside-release pushbars, and perimeter heating cables to prevent seal freezing in negative temperature chambers.

Clear Opening Net Geçiş: 90x190 cm'den 300x350 cm'ye kadar
Fire Class B-s2, d0
Reference Price
$456/ Unit
EXW TurkeyExcl. VAT
Hygienic PVC & Trims SP-COLD-ACC

Sanitary curved PVC coving profiles eliminate 90-degree internal corners between floors, walls, and ceilings in cold rooms and food facilities. Certified to international HACCP standards, they prevent bacterial growth, facilitate high-pressure washdown, and ensure zero dirt accumulation.

Coving Radius R50 mm / R70 mm / R100 mm Kavis Yarıçapı
Fire Class B-s2, d0 / Yangın Geciktirici Katkılı PVC
Reference Price
$4.20/ m²
EXW TurkeyExcl. VAT
Cold Storage Panel SP-COLD-SHOCK

Designed specifically for -40°C blast freezing tunnels and commercial sub-zero preservation, these panels incorporate an extended double-stepped labyrinth edge profile combined with heavy-duty internal eccentric cam-locks, preventing thermal leakage under extreme temperature differentials.

Modular Width 1000 mm – 1150 mm
Fire Class B-s1, d0 (FM Global Onaylı / Minimum Duman)
Reference Price
$33.00/ m²
EXW TurkeyExcl. VAT
ENGINEERING SPECIFICATION MATRIX

Insulation Core & Performance Comparison

Compare lambda thermal conductivities, fire ratings, densities and ideal project usages.

Temperature Regime Room Temp Recommended Thickness Joint Type Floor Detail Typical Use
Serin Muhafaza & İşleme +10°C / +15°C 60 – 80 mm PUR Çift Geçmeli Zıvana Yalıtımsız / İnce Şap Meat/produce processing, packing halls, logistics staging zones
Pozitif Soğuk Depo 0°C / +4°C 80 – 100 mm PUR Kam Kilitli / Labirent Plywood veya Beton Altı Fresh fruit, dairy, beverage and fresh meat cold rooms
Donuk Muhafaza (Deep Freeze) -18°C / -25°C 120 – 150 mm PIR Kam Kilitli Labirent Çift Kat XPS + Rezistans Frozen food storage, ice cream, seafood and meat blast freezers
Şoklama Tüneli (Blast Freeze) -35°C / -40°C 150 – 200 mm PIR Ağır Kam Kilit + Çift Mastik Taban Havalandırmalı Beton Rapid blast freezing tunnels, meat processing, industrial cryo
STRUCTURAL LOAD & LOGISTICS ANALYSIS

Thickness, U-Value, Weight & Logistics Matrix

Verify thermal resistance (R), permissible purlin spans and truckload volume per thickness.

EN 14509 Standard Compliant
Thickness Temperature Regime Transmittance (U) Dead Weight Ceiling Span Truckload Capacity
60 mm +12°C / +15°C (İşleme) 0.37 W/m²K 10.90 kg/m² 3.00 metre ≈ 1.000 m² / Tır
80 mm +2°C / +6°C (Soğuk Depo) 0.27 W/m²K 11.70 kg/m² 3.50 metre ≈ 800 m² / Tır
100 mm -2°C / +2°C (Et/Balık Taze) 0.22 W/m²K 12.50 kg/m² 4.00 metre ≈ 650 m² / Tır
120 mm -18°C / -22°C (Donuk) 0.18 W/m²K 13.30 kg/m² 4.50 metre ≈ 540 m² / Tır
150 mm -25°C / -30°C (Dondurucu) 0.14 W/m²K 14.50 kg/m² 5.00 metre ≈ 430 m² / Tır
200 mm -35°C / -40°C (Şoklama) 0.11 W/m²K 16.50 kg/m² 5.50 metre ≈ 320 m² / Tır
Figures represent standard 13.60m road trailer capacity (85-90 m³) under optimal stacking.
Calculate Custom Truckload
ARCHITECTURAL & STRUCTURAL GUIDE

Critical Engineering Guidelines for System Selection

Standards for purlin spacing, live loads, fire containment and joint detailing.

1. The Eccentric Cam-Lock Fastening System

Cam-lock panels feature factory-foamed male/female eccentric hook locks operated by an Allen wrench. Turning the lock draws panels tightly together, compressing internal gaskets to form a hermetic vapor-tight seal. Panels can be disassembled and relocated without damage.

2. Hygienic Food-Safe Surface Coatings (PVC, Inox, Plastisol)

Standard coils deteriorate under heavy detergent washdowns and chemical sanitizers. We laminate panels with certified 120µm Food-Safe antibacterial PVC or AISI 304/316 stainless steel to comply with global HACCP food-contact directives.

3. Subfloor Frost-Heave Prevention & Heating Mats

Sub-zero temperatures freeze groundwater beneath foundation slabs, causing destructive frost-heave swelling. Installing underfloor electric heating cables or PVC ventilation pipes under dual-layer high-load XPS insulation protects civil foundations.

4. Pressure Relief Valves for Sub-Zero Thermal Shocks

Opening cold room doors introduces warm air that rapidly contracts, generating intense vacuum forces. Electrically heated pressure relief valves equalize internal barometric pressure, preventing wall structural collapse and door jam.

5. Ceiling Panel Suspension Engineering (T-Profiles & Rods)

Large cold ceiling spans require intermediate suspension. Threaded M12 tie rods dropped from primary roof trusses anchor heavy-duty powder-coated aluminum T-bars, preventing ceiling panel sag over long service lives.

6. Curved PVC Hygienic Covings & Sanitary Detailing

Right-angle corners harbor bacterial biofilms and resist pressure washdowns. Radius-curved sanitary PVC covings transition floor-to-wall joints smoothly, meeting stringent veterinary and food hygiene inspections.

COORDINATED ENVELOPE ACCESSORIES

Matching Flashings, Screws & Trims Package

Coordinated single-delivery guarantee: Color-matched flashings, EPDM fasteners, and covings.

Curved Hygienic PVC Coving

Transitions 90-degree floor-wall corners to eliminate bacteria and ease washdowns.

Available in Package

Ceiling Suspension T-Bars & Rods

Suspends long-span ceiling panels securely from primary steel roof trusses.

Available in Package

Sliding & Hinged Cold Room Doors

Monoblock polyurethane doors with perimeter heaters and internal safety release.

Available in Package

Heated Pressure Relief Valve

Balances interior atmospheric pressure in freezers to prevent wall deflection.

Available in Package

Wiremesh Non-Slip Floor Plywood

High-durability birch plywood withstands pallet truck traffic and humidity.

Available in Package

Food-Safe Antibacterial Sealant

Prevents mold, mildew and moisture penetration across sanitary panel seams.

Available in Package
INSTANT QUANTITY & COST CALCULATION

Panel Quantity & Logistics Calculator

LIVE CALCULATION ENGINE

Roof & Wall Sandwich Panel Quantity & Logistics Calculator

Define your building dimensions and scope (Roof, Wall or Complete Envelope) to estimate net surface area, tonnage, logistics and budget.

Estimated Material & Logistics Output
Live Calculated by Dimensions
Roof Area: 1.003 m²
Wall Area: 854 m²
Total Envelope: 1.857 m²
TOTAL COVERAGE
1.857 m² Roof + Wall
TOTAL WEIGHT
16.7 Ton ~16.713 kg
TRUCKS NEEDED
2 Tır 1 Roof + 1 Wall Truck
40FT CONTAINERS
3 Konteyner 40' High Cube Export
Estimated Material Budget (Excl. VAT)
$34.355 (Excl. VAT) *All prices exclude VAT (~$18.50/sqm excl. VAT). Ex-works indicative cost. Contact us for official quote.
Request WhatsApp Quote
FREQUENTLY ASKED QUESTIONS

Frequently Asked Technical Questions

Detailed engineering answers on pricing, fire codes, installation spans and delivery.

How to determine cold room panel thickness?
Thickness depends on internal temperature: +15°C preparation halls need 60-80mm; 0°C/+4°C cold storage requires 80-100mm; -18°C/-25°C deep freezers require 120-150mm; and -40°C blast tunnels require 150-200mm PIR panels.
What is the advantage of cam-lock cold storage panels?
Cam-locks are internal eccentric hook fasteners foamed into the core. Turning an Allen wrench locks panels together hermetically without through-screws, eliminating thermal bridges and allowing modular disassembly and relocation.
How should cold room floors be insulated?
Positive rooms (+4°C) can utilize non-slip plywood floor panels. Sub-zero freezer rooms with forklift traffic require subfloor heating cables, dual-layer high-load XPS insulation and reinforced concrete screed.
Why are frame heaters necessary on cold storage doors?
In freezing environments, airborne humidity condenses and freezes around the perimeter gasket, cementing the door shut. Integrated frame heating cables prevent ice formation and gasket damage.
What is the purpose of Food-Safe PVC film coating?
120-micron antibacterial Food-Safe PVC laminate protects steel against organic food acids, blood, dairy residues and aggressive chlorinated washdowns, meeting HACCP standards.
Why is a pressure relief valve mandatory for deep freeze rooms?
Cooling air creates immediate vacuum pressure upon door closure. Heated pressure relief valves equalize internal atmospheric pressure, preventing structural envelope damage.
How many square meters of cold storage panels fit in a truckload?
A standard road trailer carries approximately 800 m² of 80mm, 650 m² of 100mm, 540 m² of 120mm, or 430 m² of 150mm cold room panels.
What is the maximum unsupported ceiling span for cold room panels?
100mm panels bridge up to 4.00m unsupported. Spans exceeding 4.00m require intermediate suspension from roof beams via threaded tie rods and aluminum T-bars.