SERPAN METAL® Roofing, Cladding & Building Envelopes
ARCHITECTURAL FACADE & FIREWALLS B2B Project Supply

Wall and Facade Sandwich Panels: Architectural Aesthetics & Energy Efficiency

Our wall and facade sandwich panel systems combine premium architectural aesthetics with high thermal performance. Available in standard through-fix (W) and concealed-fix (WM / secret-fix) configurations, they accommodate horizontal and vertical orientations with micro-ribbed or flat surface options, backed by 120-minute A1 rockwool fire barriers.

EN 14509 & CE
Custom Cut Length
Export & Truckload
Coordinated Trims
SYSTEM HIGHLIGHTS
Core Options: PUR • PIR • Taşyünü • EPS
Thickness Range: 40 mm – 200 mm
Steel Gauges: 0.40 – 0.70 mm (DX51D)
Fire Reaction: A1 Yanmaz / B-s1, d0
Max Length: 13.50 Metre (Firesiz)
TCMB Exchange Rate: 1 $ = 48,32 TL

* All prices EXW Factory excluding VAT.

WHY CHOOSE THIS SYSTEM?

Key Engineering & Commercial Benefits

Concealed-Fix Architectural Facade

Interlocking tongue-and-groove pockets conceal fasteners, creating a screw-free monolithic facade.

Double Interlocking Air Barrier

Precision factory gaskets eliminate thermal bridging and uncontrolled air leakage through joints.

Horizontal & Vertical Versatility

Engineered for direct span across primary columns horizontally or facade girts vertically.

A1 Non-Combustible 120-Min Firewall

Dense stone wool core options deliver certified 120-minute structural fire containment (EI120).

PRODUCT RANGE

Available Systems & Models

Select the optimal profile and core configuration for your building envelope requirements.

6 Systems Listed
PUR (Poliüretan) SP-WALL-PUR

Standard PUR wall panels provide fast installation and dependable weather sealing for exterior walls and internal partitions in warehouses and production facilities.

Cover Width 1000 mm (1 Metre Net)
Fire Class B-s2, d0 (Standart Yangın Dayanımı)
Reference Price
$17.00/ m²
EXW TurkeyExcl. VAT
PIR (FM Onaylı) SP-WALL-PIR

Engineered with an isocyanurate chemical ring structure that chars on flame contact without dripping, PIR wall panels satisfy stringent building code and industrial insurance (FM Global) requirements.

Cover Width 1000 mm (1 Metre Net)
Fire Class B-s1, d0 (FM Global Uyumlu / Alev Yürütmez)
Reference Price
$18.00/ m²
EXW TurkeyExcl. VAT
PUR (Poliüretan) SP-WALL-CONC

Concealed-fix panels hide all fasteners within the joint tongue, creating clean architectural shadow lines, uniform facades and preventing water ingress at screw points.

Cover Width 1000 mm (1 Metre Net)
Fire Class B-s2, d0 (PUR) / B-s1, d0 (PIR FM Onaylı)
Reference Price
$20.00/ m²
EXW TurkeyExcl. VAT
Rockwool (A1 Fire) SP-WALL-ROCK

Manufactured with vertically oriented high-density rockwool basalt slabs (100 kg/m³) to deliver structural stability, acoustic damping, and Class A1 non-combustible fire resistance up to EI 120. Ideal for industrial firewalls, hazardous storage, petrochemical plants, and building envelopes requiring official fire department accreditation.

Cover Width 1000 mm (1 Metre Net)
Fire Class A1 Hiç Yanmaz / EI 60 – EI 120
Reference Price
$21.50/ m²
EXW TurkeyExcl. VAT
EPS Yalıtım SP-WALL-EPS

EPS wall sandwich panels offer the most budget-friendly envelope solution for modular container camps, temporary construction offices, partition walls, and prefabricated housing.

Cover Width 1000 mm (1 Metre Net)
Fire Class E Sınıfı (Alev Geciktirici B1 Opsiyonel)
Reference Price
$13.50/ m²
EXW TurkeyExcl. VAT
Rockwool (A1 Fire) SP-WALL-PERF

Engineered with internal factory-perforated steel facings and an acoustic fleece backing, these rockwool panels provide exceptional sound absorption (NRC 0.85) alongside A1 non-combustible fire barrier protection for power plants and manufacturing floors.

Cover Width 1000 mm (1 Metre Net)
Fire Class A1 Sınıfı Kesin Yanmaz (Akustik Tüllü)
Reference Price
$25.50/ m²
EXW TurkeyExcl. VAT
ENGINEERING SPECIFICATION MATRIX

Insulation Core & Performance Comparison

Compare lambda thermal conductivities, fire ratings, densities and ideal project usages.

Wall Panel Model Joint System Core Material Fire Rating Aesthetic Level Best Application
SP-WALL-PUR (Vidalı W) Standart Vidalı (W) PUR (40 kg/m³) B-s2, d0 Endüstriyel Temiz Standard industrial warehouses, factories and exterior workshops
SP-WALL-PIR (Vidalı W) Standart Vidalı (W) PIR (42 kg/m³) B-s1, d0 (FM) Endüstriyel Yüksek Large-scale industrial plants requiring certified fire performance
SP-WALL-CONC (Gizli WM) Gizli Vidalı (WM) PIR / PUR Dolgulu B-s1, d0 / B-s2,d0 Premium Mimari Showrooms, corporate headquarters, retail facades (100% hidden fixings)
SP-WALL-ROCK (Yangın Duvarı) Gizli / Standart Taşyünü (100 kg/m³) A1 Sınıfı (120 Dk) Yüksek Güvenlik Fire break partition walls, generator rooms, hazardous production plants
SP-WALL-EPS (Modüler Duvar) Standart Vidalı EPS (16-20 kg/m³) E Sınıfı Ekonomik Hafif Internal partition walls, site offices, low-budget dry storage
STRUCTURAL LOAD & LOGISTICS ANALYSIS

Thickness, U-Value, Weight & Logistics Matrix

Verify thermal resistance (R), permissible purlin spans and truckload volume per thickness.

EN 14509 Standard Compliant
Thickness Wind Load Bearing Transmittance (U) Dead Weight Rec. Girt Span Truckload Capacity
40 mm (Vidalı W) 90 kg/m² 0.55 W/m²K 9.80 kg/m² 2.00 – 2.20 m ≈ 1.400 m² / Tır
50 mm (Gizli WM) 120 kg/m² 0.44 W/m²K 10.20 kg/m² 2.20 – 2.50 m ≈ 1.200 m² / Tır
60 mm (Gizli WM) 150 kg/m² 0.37 W/m²K 10.60 kg/m² 2.50 – 2.80 m ≈ 1.050 m² / Tır
80 mm (Gizli WM) 190 kg/m² 0.27 W/m²K 11.40 kg/m² 2.80 – 3.20 m ≈ 850 m² / Tır
100 mm (Gizli WM) 240 kg/m² 0.22 W/m²K 12.20 kg/m² 3.20 – 3.60 m ≈ 700 m² / Tır
100 mm Taşyünü (A1) 260 kg/m² 0.38 W/m²K 21.00 kg/m² 2.50 – 2.80 m ≈ 520 m² / Tır
Figures represent standard 13.60m road trailer capacity (85-90 m³) under optimal stacking.
Calculate Custom Truckload
ARCHITECTURAL & STRUCTURAL GUIDE

Critical Engineering Guidelines for System Selection

Standards for purlin spacing, live loads, fire containment and joint detailing.

1. Standard Through-Fix vs. Concealed-Fix (Secret-Fix)

Standard through-fix (W) panels expose fastener heads fitted with color-matched caps, offering fast installation and low cost. Concealed-fix (WM / secret-fix) panels feature an interlocking tongue-and-groove joint where screws are hidden inside the joint pocket, creating an uninterrupted architectural monolithic facade.

2. Horizontal vs. Vertical Wall Panel Installation

Vertical installation runs continuous lengths from parapet to slab, fastening directly to horizontal wall girts. Horizontal installation fixes panels across building columns, creating contemporary linear proportions. Column joint lines are detailed with matching flashings or architectural aluminum extrusions.

3. Wind Suction Load Calculation & Facade Girt Sizing

Wind suction generates intense outward loads, especially on building corners and parapet perimeters. Girt spacing should range between 2.20m and 2.50m for 50mm panels, reinforced with dual fixing clips at vulnerable building corners.

4. Fire Compartment Partition Walls & Permitting Standards

Industrial fire codes mandate non-combustible A1 materials along plot boundaries and partition firewalls. 100mm Rockwool panels deliver EI120 fire barrier ratings required for municipal fire compliance approvals.

5. Micro-Ribbed, Linear and Flat Facade Surface Finishes

Micro-ribbed profiles prevent optical wave distortion (oil-canning) on long exterior facades. Flat finishes with reinforced 0.60-0.70mm steel gauges provide crisp architectural minimalism.

6. Base Drip, Corner Flashing & Weatherproofing Details

Panels never sit directly on raw concrete. A base galvanized U-channel bedded in butyl sealant provides level alignment, paired with sub-base drip flashings to shed rainwater safely clear of foundations.

COORDINATED ENVELOPE ACCESSORIES

Matching Flashings, Screws & Trims Package

Coordinated single-delivery guarantee: Color-matched flashings, EPDM fasteners, and covings.

Bottom Base U-Channel

Prevents panels from contacting raw concrete and ensures plumb alignment.

Available in Package

External & Internal Corner Flashings

Weatherproofs external and internal corner junctions against driving rain.

Available in Package

Base Drip Flashing

Directs facade runoff away from foundations and concrete plinths.

Available in Package

Secret-Fix Mounting Clips

Clamps interlocking tongue-and-groove joints without surface damage.

Available in Package

Polyurethane Facade Sealant

Completes air and vapor tightness along longitudinal joints and flashings.

Available in Package

Aluminum Omega & Joint Profiles

Cleanly covers horizontal stack joints across column gridlines.

Available in Package
INSTANT QUANTITY & COST CALCULATION

Panel Quantity & Logistics Calculator

LIVE CALCULATION ENGINE

Roof & Wall Sandwich Panel Quantity & Logistics Calculator

Define your building dimensions and scope (Roof, Wall or Complete Envelope) to estimate net surface area, tonnage, logistics and budget.

Estimated Material & Logistics Output
Live Calculated by Dimensions
Roof Area: 1.003 m²
Wall Area: 854 m²
Total Envelope: 1.857 m²
TOTAL COVERAGE
1.857 m² Roof + Wall
TOTAL WEIGHT
16.7 Ton ~16.713 kg
TRUCKS NEEDED
2 Tır 1 Roof + 1 Wall Truck
40FT CONTAINERS
3 Konteyner 40' High Cube Export
Estimated Material Budget (Excl. VAT)
$34.355 (Excl. VAT) *All prices exclude VAT (~$18.50/sqm excl. VAT). Ex-works indicative cost. Contact us for official quote.
Request WhatsApp Quote
FREQUENTLY ASKED QUESTIONS

Frequently Asked Technical Questions

Detailed engineering answers on pricing, fire codes, installation spans and delivery.

What is the difference between secret-fix and standard wall panels?
Concealed-fix (WM) panels conceal fasteners within the tongue-and-groove joint profile, leaving a clean architectural exterior with zero visible screws. Standard through-fix (W) panels are fastened from the exterior with visible painted screw heads.
What panel thickness is required for fire walls?
For structural fire barriers, minimum 80mm to 100mm A1 non-combustible Rockwool panels (`SP-WALL-ROCK`) are standard. A 100mm Rockwool panel delivers up to 120 minutes (EI120) fire containment integrity.
Should wall panels be installed horizontally or vertically?
Both methods are supported. Vertical installation runs continuous lengths from parapet to slab. Horizontal installation fixes panels across building columns, creating contemporary linear proportions.
What thickness is standard for industrial factory facades?
50mm and 60mm PUR/PIR panels are industry standard for factory envelopes. Mild coastal zones can use 40mm, while cold continental regions specify 80mm.
How many square meters of wall panels fit in a truckload?
A standard trailer transports approximately 1,400 m² of 40mm, 1,200 m² of 50mm, 1,050 m² of 60mm, or 700 m² of 100mm wall panels.
How is wind suction calculated for wall panels?
Panels resist outward suction forces. Perimeter corner zones require closer girt spans or dual mounting clips to handle 40% higher suction forces.
What colors and coatings are available for facade panels?
RAL 9002 (Off-White), RAL 7016 (Anthracite Grey) and RAL 9006 (Metallic Silver) are standard with 25µm Polyester or marine-grade PVDF/Plastisol finishes.
Which panel is recommended for interior partitions?
Economical 40mm or 50mm EPS or PUR wall panels are ideal for interior dry partitions and site offices. Hazardous utility rooms mandate A1 Rockwool.
DIRECT ENGINEERING & LOGISTICS SUPPORT

Ready to Receive a Factory-Direct Project Quotation?

Share your project drawings or quantity takeoffs; our engineering team will provide a comprehensive commercial offer within 2 hours.

Direct Manufacturer Pricing Net Base Rates (Excl. VAT) Global Export Packing Custom Project Lengths