SERPAN METAL® Roofing, Cladding & Building Envelopes
10 • BALIKESIR Marmara Region TS 825 2. THERMAL ZONE

Balikesir Sandwich Panels, Roofing & Building Envelope Systems

Supplying cold storage panels, acid-resistant agro panels, and industrial roofing across Balikesir and Bandirma port zones.

Distance from Plant
210 km
Gebze Logistics Hub
Truckload Transit
3 – 4 Hours via Istanbul–Izmir Motorway
Direct to Jobsite
Insulation Standard
TS 825 (2)
Rec: 50mm – 60mm PIR
Districts Covered
20 Districts
Full Coverage
EN 14509 CODE COMPLIANCE

Balikesir Recommended Panel & Profile Specifications

Statical configurations optimized for Balikesir wind load, snow pressure, and building thermal regulations:

ROOF SYSTEM 5-Ribbed

5-Rib High Capacity Roof Panels

Engineered for Balikesir climate conditions. Heavy gauge steel with 50mm – 60mm PIR high-performance core.

Facing Gauges: 0.50mm / 0.40mm
Fire Class: B-s1,d0 (PIR) / A1 (Rockwool)
Panel Lengths: 2.00m – 13.50m
View Specifications
WALL CLADDING Secret / Standard Fix

Architectural Wall Panels

Weather-tight concealed fastener joints engineered to resist Balikesir regional wind loads.

Core Insulation: 50mm PUR / PIR
Surface Pattern: Micro-rib / Flat
Coating: 25µ Poly / 50µ PVDF
View Specifications
STRUCTURAL PURLINS C & Z Purlins

Galvanized C / Z Steel Purlins

Cold-formed from certified S350GD structural steel with 275 g/m² zinc coating for superior corrosion protection.

Thickness: 1.50mm – 3.50mm
Depth: 100mm – 350mm
Punching: CNC Pre-Punched
View Specifications

Balikesir Frequently Asked Questions

Logistics guidelines, jobsite offloading protocols, and technical insulation inquiries for Balikesir.

? What is the estimated delivery transit time to Balikesir?

From our central manufacturing hub in Kocaeli/Gebze, the road distance to Balikesir is approximately 210 km. Full truckload orders are dispatched directly to the jobsite with an average transit of 3 – 4 Hours via Istanbul–Izmir Motorway.

? Which insulation thickness is recommended for Balikesir building regulations?

Balikesir belongs to Thermal Insulation Zone 2 under Turkish standard TS 825. For industrial envelopes, we recommend at least 50mm – 60mm PIR for roofs to achieve required thermal resistance.

? Can panels be custom-cut to project measurements for Balikesir sites?

Yes. We supply continuous factory-manufactured panels custom-cut from 2.00m up to 13.50m matching your exact purlin spans, eliminating cutting scrap and speeding up installation on site.

Balikesir Request Site Quotation for Balikesir

Submit your project dimensions to receive a comprehensive factory-direct quotation including freight.