SERPAN METAL® Roofing, Cladding & Building Envelopes
72 • BATMAN Southeastern Anatolia Region TS 825 2. THERMAL ZONE

Batman Sandwich Panels, Roofing & Building Envelope Systems

High-performance thermal envelope supply for industrial parks and export infrastructure across Batman.

Distance from Plant
1288 km
Gebze Logistics Hub
Truckload Transit
24 – 48 Hours
Direct to Jobsite
Insulation Standard
TS 825 (2)
Rec: 50mm – 60mm PIR
Districts Covered
6 Districts
Full Coverage
DISTRICT DIRECTORY

Batman Districts & Industrial Zones

Select your district to review site access guidelines, local industrial hubs, and technical recommendations:

6 Dedicated District Pages
EN 14509 CODE COMPLIANCE

Batman Recommended Panel & Profile Specifications

Statical configurations optimized for Batman wind load, snow pressure, and building thermal regulations:

ROOF SYSTEM 5-Ribbed

5-Rib High Capacity Roof Panels

Engineered for Batman climate conditions. Heavy gauge steel with 50mm – 60mm PIR high-performance core.

Facing Gauges: 0.50mm / 0.40mm
Fire Class: B-s1,d0 (PIR) / A1 (Rockwool)
Panel Lengths: 2.00m – 13.50m
View Specifications
WALL CLADDING Secret / Standard Fix

Architectural Wall Panels

Weather-tight concealed fastener joints engineered to resist Batman regional wind loads.

Core Insulation: 50mm PUR / PIR
Surface Pattern: Micro-rib / Flat
Coating: 25µ Poly / 50µ PVDF
View Specifications
STRUCTURAL PURLINS C & Z Purlins

Galvanized C / Z Steel Purlins

Cold-formed from certified S350GD structural steel with 275 g/m² zinc coating for superior corrosion protection.

Thickness: 1.50mm – 3.50mm
Depth: 100mm – 350mm
Punching: CNC Pre-Punched
View Specifications

Batman Frequently Asked Questions

Logistics guidelines, jobsite offloading protocols, and technical insulation inquiries for Batman.

? What is the estimated delivery transit time to Batman?

From our central manufacturing hub in Kocaeli/Gebze, the road distance to Batman is approximately 1288 km. Full truckload orders are dispatched directly to the jobsite with an average transit of 24 – 48 Hours.

? Which insulation thickness is recommended for Batman building regulations?

Batman belongs to Thermal Insulation Zone 2 under Turkish standard TS 825. For industrial envelopes, we recommend at least 50mm – 60mm PIR for roofs to achieve required thermal resistance.

? Can panels be custom-cut to project measurements for Batman sites?

Yes. We supply continuous factory-manufactured panels custom-cut from 2.00m up to 13.50m matching your exact purlin spans, eliminating cutting scrap and speeding up installation on site.

Batman Request Site Quotation for Batman

Submit your project dimensions to receive a comprehensive factory-direct quotation including freight.