SERPAN METAL® Roofing, Cladding & Building Envelopes
31 • HATAY Mediterranean Region TS 825 1. THERMAL ZONE

Hatay Sandwich Panels, Roofing & Building Envelope Systems

Supplying heavy metallurgy plants in Isdemir/Payas and post-disaster reconstruction projects across Antakya and Hatay.

Distance from Plant
990 km
Gebze Logistics Hub
Truckload Transit
10 – 12 Hours
Direct to Jobsite
Insulation Standard
TS 825 (1)
Rec: 50mm PIR / Taşyünü
Districts Covered
15 Districts
Full Coverage
EN 14509 CODE COMPLIANCE

Hatay Recommended Panel & Profile Specifications

Statical configurations optimized for Hatay wind load, snow pressure, and building thermal regulations:

ROOF SYSTEM 5-Ribbed

5-Rib High Capacity Roof Panels

Engineered for Hatay climate conditions. Heavy gauge steel with 50mm PIR / Taşyünü high-performance core.

Facing Gauges: 0.50mm / 0.40mm
Fire Class: B-s1,d0 (PIR) / A1 (Rockwool)
Panel Lengths: 2.00m – 13.50m
View Specifications
WALL CLADDING Secret / Standard Fix

Architectural Wall Panels

Weather-tight concealed fastener joints engineered to resist Hatay regional wind loads.

Core Insulation: 50mm PUR / PIR
Surface Pattern: Micro-rib / Flat
Coating: 25µ Poly / 50µ PVDF
View Specifications
STRUCTURAL PURLINS C & Z Purlins

Galvanized C / Z Steel Purlins

Cold-formed from certified S350GD structural steel with 275 g/m² zinc coating for superior corrosion protection.

Thickness: 1.50mm – 3.50mm
Depth: 100mm – 350mm
Punching: CNC Pre-Punched
View Specifications

Hatay Frequently Asked Questions

Logistics guidelines, jobsite offloading protocols, and technical insulation inquiries for Hatay.

? What is the estimated delivery transit time to Hatay?

From our central manufacturing hub in Kocaeli/Gebze, the road distance to Hatay is approximately 990 km. Full truckload orders are dispatched directly to the jobsite with an average transit of 10 – 12 Hours.

? Which insulation thickness is recommended for Hatay building regulations?

Hatay belongs to Thermal Insulation Zone 1 under Turkish standard TS 825. For industrial envelopes, we recommend at least 50mm PIR / Taşyünü for roofs to achieve required thermal resistance.

? Can panels be custom-cut to project measurements for Hatay sites?

Yes. We supply continuous factory-manufactured panels custom-cut from 2.00m up to 13.50m matching your exact purlin spans, eliminating cutting scrap and speeding up installation on site.

Hatay Request Site Quotation for Hatay

Submit your project dimensions to receive a comprehensive factory-direct quotation including freight.