SERPAN METAL® Roofing, Cladding & Building Envelopes
39 • KIRKLARELI Marmara Region TS 825 2. THERMAL ZONE

Kirklareli Sandwich Panels, Roofing & Building Envelope Systems

Supplying glass manufacturing, textile, and agro-storage facilities across Luleburgaz and Buyukkaristiran industrial corridors.

Distance from Plant
190 km
Gebze Logistics Hub
Truckload Transit
2.5 – 3 Hours
Direct to Jobsite
Insulation Standard
TS 825 (2)
Rec: 50mm – 60mm PIR
Districts Covered
8 Districts
Full Coverage
EN 14509 CODE COMPLIANCE

Kirklareli Recommended Panel & Profile Specifications

Statical configurations optimized for Kirklareli wind load, snow pressure, and building thermal regulations:

ROOF SYSTEM 5-Ribbed

5-Rib High Capacity Roof Panels

Engineered for Kirklareli climate conditions. Heavy gauge steel with 50mm – 60mm PIR high-performance core.

Facing Gauges: 0.50mm / 0.40mm
Fire Class: B-s1,d0 (PIR) / A1 (Rockwool)
Panel Lengths: 2.00m – 13.50m
View Specifications
WALL CLADDING Secret / Standard Fix

Architectural Wall Panels

Weather-tight concealed fastener joints engineered to resist Kirklareli regional wind loads.

Core Insulation: 50mm PUR / PIR
Surface Pattern: Micro-rib / Flat
Coating: 25µ Poly / 50µ PVDF
View Specifications
STRUCTURAL PURLINS C & Z Purlins

Galvanized C / Z Steel Purlins

Cold-formed from certified S350GD structural steel with 275 g/m² zinc coating for superior corrosion protection.

Thickness: 1.50mm – 3.50mm
Depth: 100mm – 350mm
Punching: CNC Pre-Punched
View Specifications

Kirklareli Frequently Asked Questions

Logistics guidelines, jobsite offloading protocols, and technical insulation inquiries for Kirklareli.

? What is the estimated delivery transit time to Kirklareli?

From our central manufacturing hub in Kocaeli/Gebze, the road distance to Kirklareli is approximately 190 km. Full truckload orders are dispatched directly to the jobsite with an average transit of 2.5 – 3 Hours.

? Which insulation thickness is recommended for Kirklareli building regulations?

Kirklareli belongs to Thermal Insulation Zone 2 under Turkish standard TS 825. For industrial envelopes, we recommend at least 50mm – 60mm PIR for roofs to achieve required thermal resistance.

? Can panels be custom-cut to project measurements for Kirklareli sites?

Yes. We supply continuous factory-manufactured panels custom-cut from 2.00m up to 13.50m matching your exact purlin spans, eliminating cutting scrap and speeding up installation on site.

Kirklareli Request Site Quotation for Kirklareli

Submit your project dimensions to receive a comprehensive factory-direct quotation including freight.